The money is about to go on the face
When an owner in Westminster is about to spend on a honed limestone surround and a new insert, the chimney behind the wall is the last thing they feel like paying to look at. It is also the part that decides whether the new fireplace can be lit at all. A camera run before the design is fixed costs $410 on our list, and it protects every dollar that follows it.
What the fire code asks for
NFPA 211 is the fire code document that covers chimneys and fireplaces, and it names the occasions when the deeper Level 2 inspection is due. Switching fuel, setting a new appliance into an existing opening and relining a flue are among them. That places nearly every remodel that adds an insert or a gas log set firmly on the Level 2 side.
A refacing that keeps a wood fireplace burning wood exactly as before may not trigger it. Even then we look at the firebox and up past the damper on the measuring visit, because a new face should not go up around a problem.
For comparison, our Level 1 at $175 is a look with a strong light at the parts you can reach from the hearth and the roof. Level 2 feeds a video camera from the smoke chamber to the cap and adds the roof and the attic space beside the chimney.
What the camera finds that changes a remodel
- Cracked or offset clay tiles. An insert can still go in, but it will need a stainless liner from top to bottom. That is a cost to know about before the stone is ordered. More on that in the liner behind a new insert.
- Heavy deposits from years of wood fires. A sweep comes before anything else, and the camera goes back in afterward if the deposits hid the tile.
- A flue that is the wrong size for the unit you picked. That can change the model, and with it the trim size and the proportions of the surround.
- Gaps where the chimney passes the house framing. Better found while the wall is open than after it is closed under plaster.
- Water tracks inside the flue. Fixed before the new finish goes up, or the first winter storm stains it.
Why before the design, not after
Run the sequence the other way and see where it goes. The slab is cut, the mantel is milled, the insert is on the truck, and then the flue turns out to be cracked at second-floor height. The liner adds cost and the install date moves. Worse, a finding at the hearth or the framing can mean the surround has to sit differently from the drawing.
With the camera run first, the design starts from what the chimney can actually carry. Sizes are right the first time, the quote carries no unknowns, and the finish goes up once.
What decides the price
The inspection itself has fixed prices: $175 for Level 1 and $410 for Level 2. The part that varies is whatever the report sets in motion. Some of those fixes have published figures too: finding plus sealing a leak is $585 to $3,500. A cap over the flue is quoted after we measure. Size, material and the chimney itself set the price. Liner, crown and damper repairs go on the written remodel quote as their own lines, once the camera has shown what is there.
Book the Level 2 through the quote form and add a line about the remodel you are planning. The report then feeds straight into the design and into the written quote for the fireplace.
What you receive
You get a written report with stills from the video. Each still carries a short note: what it shows, and whether it blocks the remodel, changes it or can wait. If nothing stands in the way, the report says that plainly, and the design goes ahead on firm ground.
The report is yours to keep. If you choose another installer for the finish work, it travels with you.
For a remodel we add one more thing: the inside measurements of the flue and the opening, written on the report beside the stills. Those numbers decide which insert models will fit and how wide the trim will be, so the surround can be drawn around real sizes rather than a brochure.
Questions owners ask
My home inspector looked at the fireplace when we bought the house. A purchase inspection covers the whole home in one visit, and few of them put a camera inside the flue. The remodel is a new trigger in any case: the fuel or the appliance is changing.
Is it worth it if we are only painting the brick? If the fuel stays the same and nothing else changes, our look on the measuring visit is usually enough. A Level 2 is then your call.
Does the camera make a mess? Drop cloths go down and a vacuum runs while the camera is in. The room is left as we found it.
Can the inspection and the remodel happen on the same visit? The camera run comes first so the design can follow from it. Measuring for the finish can happen on the same trip.
See the Level 2 inspection page for what the camera covers in full.
Before you choose a finish in Westminster
If a new fireplace face is on your list, begin on our contact page. We will set up the camera run, then sit down with you over finishes once we know what the chimney can take.
Want This Done on Your Own Fireplace?
Bancroft Chimney Works measures the wall, brings tile and stone samples and checks the firebox before writing a scope. Homes in Westminster, Garden Grove, Huntington Beach and Lakewood are all within reach.